 75W Single Output LED Power Supply
1/2 Features :
CEN-75
series
Universal AC input / Full range (up to 295VAC) Protections: Short circuit / Overload / Over voltage / Over temperature Output voltage and constant current level adjustable Built-in active PFC function IP66 design for indoor or outdoor installations Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty
F
110
M
M
SELV
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CEN-75-15 15V 5A 0 ~ 5A 75W CONSTANT CURRENT OPERATION VOLTAGE Note.5 11.25 ~ 15V CEN-75-20 20V 15 ~ 20V 3.75A 0 ~ 3.75A 75W 2Vp-p 17 ~ 22V 2.81 ~ 3.75A CEN-75-24 24V 18 ~ 24V 3.15A 0 ~ 3.15A 75.6W 2.7Vp-p 22 ~ 27V 2.36 ~ 3.15A CEN-75-30 30V 22.5 ~ 30V 2.5A 0 ~ 2.5A 75W 3Vp-p 27 ~ 33V 1.88 ~ 2.5A
IP66
CEN-75-36 36V 27 ~ 36V 2.1A 0 ~ 2.1A 75.6W 3.6Vp-p 33 ~ 40V 1.58 ~ 2.1A CEN-75-42 42V 31.5 ~ 42V 1.8A 0 ~ 1.8A 75.6W 4Vp-p 37 ~ 46V 1.35 ~ 1.8A CEN-75-48 48V 36 ~ 48V 1.57A 0 ~ 1.57A 75.36W 4.6Vp-p 43 ~ 53V 1.18 ~ 1.57A CEN-75-54 54V 40.5 ~ 54V 1.4A 0 ~ 1.4A 75.6W 5Vp-p 49 ~ 58V 1.05 ~ 1.4A
RIPPLE & NOISE (max.) Note.2 2.7Vp-p VOLTAGE ADJ. RANGE (SVR1) 13.5 ~ 17V CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC ISOLATION RESISTANCE 10% 3.0% 5.0%
1400ms / 230VAC 2800ms / 115VAC at full load
Note.4 90 ~ 295VAC
127 ~ 417VDC PF>0.95 / 230VAC at full load 90% 91% 91%
47 ~ 63Hz PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC 87% 1.1A/115VAC 45A/230VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V 41 ~ 46V Protection type : Shut down o/p voltage, re-power on to recover 85 10 (RTH1) (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 -40 ~ +80 0.03%/ 20 ~ 95% RH non-condensing 47 ~ 52V 54 ~ 60V 59 ~ 65V 88% 0.55A/230VAC 89% 90% 90%
<0.75mA / 240VAC
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, TUV EN61347-1, EN61347-2-13, IP66 approved I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC / 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55015 Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A 522.2Khrs min. MIL-HDBK-217F (25 ) 183*62.5*40.5mm (L*W*H) 0.56Kg;24pcs/14.4Kg/1.11CUFT
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 75% ~ 100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:CEN-75-SPEC 2010-09-01
75W Single Output LED Power Supply
Mechanical Specification
CEN-75
Case No.993B
series
Unit:mm
183 10.5 7.6 162
300 20
300 20
30.6 45 62.5
Vo Io ADJ. ADJ.
AC/L(Brown) AC/N(Blue) FG (Green/Yellow)
18AWG 3C SJTW 4.6 4PL
18AWG 2C SVT
+V(Red) -V(Black)
Block Diagram
RECTIFIERS & FILTER DETECTION CIRCUIT PWM & PFC CONTROL O.V.P.
fosc : 50KHz(115VAC) 75KHz(230VAC)
POWER SWITCHING +V -V
I/P
EMI FILTER & RECTIFIERS
FG
O.L.P.
O.C.P.
Derating Curve
Static Characteristics
Ta:25
100
100 90
80
80 70
60
LOAD (%)
40
LOAD (%)
60 50 40
20
-30
-25
-5
0
15
30
50
60
70
(HORIZONTAL)
90
100
125
135
145
155 165
175
180
200
230
295
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:CEN-75-SPEC 2010-09-01
40.5
75W Single Output LED Power Supply
Power Factor Characteristic
Power factor will be higher than 0.9 when output loading is 75% or higher.
CEN-75
series
Constant Current Mode
1 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 .8 8 0 .8 6 0 .8 4 0 .8 2 0 .8 0 .7 8 50% 60% 70%
LOAD
PF
230VAC 110VAC
80%
90%
100%
EFFICIENCY vs LOAD (48V Model)
CEN-75 series possess superior working efficiency that up to 91% can be reached in field applications.
94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
EFFICIENCY (%)
230VAC 110VAC
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
100
(B) Constant Current area (A) Constant Voltage area
50 (max.) (C) Hiccup Protection 50 100 Io (%)
Vo(%)
Typical LED power supply I-V curve
File Name:CEN-75-SPEC 2010-09-01


▲Up To Search▲   

 
Price & Availability of CEN-75-20

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X